Publication:
Study of the Deformation by Compression of a Premolar with and Without Ceramic Restoration Using Speckle Optical Interferometry

dc.contributor.authorBaradit, Erik
dc.contributor.authorGutiérrez, Jorge
dc.contributor.authorYáñez, Miguel
dc.contributor.authorSumonte, Claudio
dc.contributor.authorAguilera, Cristhian
dc.date.accessioned2026-10-07T16:25:54Z
dc.date.available2026-10-07T16:25:54Z
dc.date.issued2025
dc.description.abstractThis work aimed to quantify axial deformations of a human premolar during occlusion with its antagonist and to compare them with the same premolar restored with a ceramic crown. The deformations were put under stress using a mechanical press with a force ranging from 1 to 100 Newtons. These deformations were quantified using the optical interferometry technique with a laser source (633 nm, 0.95 mW). Using a CMOS camera, interference fringes were obtained, stored, and subsequently processed. The premolars were restored with Cerasmart GC ceramic, using the CAD-CAM system. The average deformations of healthy premolars were found to be in a range of 0.69 to 1.74 µm, while the restored ones were deformed in a range of 0.53 to 1.10 µm. The results of this work showed that the Cerasmart ceramic material had similar properties to those of the natural tooth for small forces. However, for higher forces, the ceramics increased the coronal stiffness of the tooth. This modified the optimal combination of stiffness, strength, and resilience between the enamel and dentin, causing a decrease in the tooth’s ability to dissipate energy; therefore, the tooth could receive more stress. The observed mechanical properties lead to the conclusion that the Cerasmart material can be indicated for the restoration of anterior and premolar teeth in most cases where a fixed prosthesis is required.
dc.description.versionVersión Publicada
dc.identifier.citationBaradit, E., Gutiérrez, J., Yáñez, M., Sumonte, C., & Aguilera, C. (2025). Study of the Deformation by Compression of a Premolar with and Without Ceramic Restoration Using Speckle Optical Interferometry. Applied Sciences, 15(19), 10708. https://doi.org/10.3390/app151910708
dc.identifier.doihttps://doi.org/10.3390/app151910708
dc.identifier.urihttps://hdl.handle.net/11447/11255
dc.language.isoen
dc.subjectAxial deformation
dc.subjectDentistry
dc.subjectCeramic composite
dc.subjectOptics interferometry
dc.titleStudy of the Deformation by Compression of a Premolar with and Without Ceramic Restoration Using Speckle Optical Interferometry
dc.typeArticle
dcterms.accessRightsAcceso Abierto
dcterms.sourceApplied Sciences
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Study of the Deformation by Compression of a Premolar with and Without Ceramic Restoration Using Speckle Optical Interferometry.pdf
Size:
3.09 MB
Format:
Adobe Portable Document Format
Description:
Texto Completo
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
347 B
Format:
Item-specific license agreed upon to submission
Description: