Person:
Silva, Alvaro

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Silva

First Name

Alvaro

Name

¿Qué estás buscando?



Search Results

Now showing 1 - 2 of 2
  • Publication
    Clinical Outcome and Histological Findings After Induced Leakage of PMMA Loaded With Methotrexate and Cisplatin During Vertebroplasty: Experimental Model in Pigs
    (2023) Silva, Alvaro; Llombart-Blanco, Rafael; Gallegos Angulo, Marcela; Villas Tomé, Carlos; Olmos-García, Matías Alfonso
    Study Design: Animal experimental model. Objective: Tostudy the clinical behavior and histological changes in the spinal cord, nerve roots and perivertebral muscles of the spine after induced leakage of polymethylmethacrylate (PMMA) loaded with antiblastic drugs during vertebroplasty in an animal model of pigs. Methods: We performed vertebroplasty on 25 pigs. The animals were divided into 3 groups: vertebroplasty with PMMA alone (control group), vertebroplasty with PMMA loaded with methotrexate (MTX) and vertebroplasty with PMMA loaded with cis platin (CYS). At 2 vertebral levels, epidural and prevertebral, massive cement leaks were induced. Animals were evaluated daily. Two weeks later, the pigs were sacrificed, and the tissues that came in contact with the cement were analyzed. Results: The clinical results for each of the groups were reported. The control group had no clinical alterations. In the MTX group, 2 pigs died before 1 week due to pneumonitis. In the CYS group, 4 animals had motor impairment, and 3 of the 4 had paraplegia. The histological results were as follows: the control and MTX groups showed synovial metaplasia, inflammatory reaction, crystal deposits, and giant cell reaction in the dura mater and muscle and all the animals in the CYS group had spinal cord and muscular necrosis. Conclusions: Massive cement leak after vertebroplasty with PMMA loaded with cisplatin is extremely toxic to the spinal cord and muscles around the spine. Therefore, its use cannot be recommended for the treatment of vertebral metastases. Using PMMA loaded with methotrexate seems to be a safe procedure, but further research is needed
  • Publication
    How to Avoid and Handle Problems in the Placement of Cement-Augmented Fenestrated Percutaneous Pedicle Screws?
    (2024) Padilla, Fernando; Landriel, Federico; Guiroy, Alfredo; Casimiro, Miguel; Silva, Alvaro; Hem, Santiago
    BACKGROUND AND OBJECTIVES: Pedicle screws with a central cannula and fenestrations allow cement augmentation, providing lower risk for screw loosening and pullout, especially in these patients with poor bone quality. This study aims to offer suggestions for resolving issues and reducing complications associated with the use of cement-augmented fenestrated pedicle screws. METHODS: A retrospective study was conducted across multiple centers on patients who received fenestrated pedicle screws with cement augmentation (CAFPS). Using 2-dimensional fluoroscopy guidance, we placed over 800 screws in 137 patients. Based on our analysis of common challenges and complications, 10 tips were compiled, that we believe are crucial for successfully implementing this technique, regardless of the brand or instrument used. RESULTS: The 10 tips included the following: (1) Indications of cement-augmented fenestrated pedicle screws; (2) use the K-wire blunt end in osteoporotic vertebrae; (3) know the longitude and diameter of the screw, by the measurement of the vertebrae to treat; (4) do not go bicortical; (5) clean the way of the screws fenestrae with saline; (6) protecting screw extensors with gauze; (7) measuring time and volume; (8) gently and smoothly introduce the cement; (9) do not panic. The presence of cement in the posterosuperior area adjacent to the pedicle does not necessarily indicate a leakage into the canal; and (10) fenestrated screw removal. CONCLUSION: The implementation of these tips could enhance technique performance and minimize complications in cement-augmented fenestrated pedicle screw placement.