Functional results of burned hands treated with Integra (R)

dc.contributor.authorCuadra, Alvaro
dc.contributor.authorCorrea, Gerardo
dc.contributor.authorRoa, Ricardo
dc.contributor.authorJose, Piñeros
dc.contributor.authorNorambuena, Hernán
dc.contributor.authorSearle, Susana
dc.contributor.authorLas Heras, Rocio
dc.contributor.authorCalderon, Wilfredo
dc.date.accessioned2017-05-26T14:48:53Z
dc.date.available2017-05-26T14:48:53Z
dc.date.issued2012
dc.description.abstractINTRODUCTION: Dermal substitutes, such as Integra(®) introduced as a new alternative to our surgical arsenal and its use in burn treatment, in both acute and chronic phases, have gained great importance. OBJECTIVE: The aim of the experiment is to describe the results of the functional evaluation of patients with burned hands treated with Integra(®) in both acute and chronic phases. MATERIAL AND METHODS: A retrospective review of a transversal cohort. Patient characteristics evaluated were sociodemographic characteristics, burn mechanism, burn extension and depth, treatments received previous to Integra(®) and complications related to its use. Clinical and photographic evaluations were performed evaluating skin elasticity, range of articular movement, prehensile strength, pain and functional evaluation using the validated 400 Point Evaluation Test. RESULTS: A total of 17 burned hands in 14 right-handed patients, were treated with Integra(®), three being bilateral hand burns. Eleven were treated in the acute phase and in nine in the scar reconstruction phase. Range of articular motion was complete in 15 of 17 hands. In 88% of the hands, flexible skin coverage was achieved. No statistically significant difference was observed in prehension strength of the burned hand versus the contralateral non-burned hand. Sixteen hands had a painless evolution. The 400 Point Evaluation score was 92.8 ± 6.3% (80 - 100%). Nearly four-fifths (79%) of the patients returned to normal active working activities.
dc.format.extent7
dc.identifier.citationJournal of Plastic, Reconstructive & Aesthetic Surgery, 2012 Feb;65(2):228-34
dc.identifier.urihttp://hdl.handle.net/11447/1344
dc.identifier.urihttps://doi.org/10.1016/j.bjps.2011.09.008
dc.language.isoen_US
dc.publisherElsevier
dc.subjectHand
dc.subjectBurns
dc.subjectDermal regenerator
dc.subjectFunctional evaluation
dc.titleFunctional results of burned hands treated with Integra (R)