Does the Epi-No-(R) birth trainer prevent vaginal birth-related pelvic floor trauma? A multicentre prospective randomised controlled trial

dc.contributor.authorKamisan, Atan
dc.contributor.authorShek, K
dc.contributor.authorLanger, S
dc.contributor.authorGuzmán Rojas, Rodrigo
dc.contributor.authorCaudwell-Hall, J
dc.contributor.authorDaly, J
dc.contributor.authorDietz, H
dc.date.accessioned2017-05-12T12:52:35Z
dc.date.available2017-05-12T12:52:35Z
dc.date.issued2016
dc.description.abstractOBJECTIVE: Vaginal childbirth may result in levator ani injury secondary to overdistension during the second stage of labour. Other injuries include perineal and anal sphincter tears. Antepartum use of a birth trainer may prevent such injuries by altering the biomechanical properties of the pelvic floor. This study evaluates the effects of Epi-No(®) use on intrapartum pelvic floor trauma. DESIGN: Multicentre prospective randomised controlled trial. SETTING: Two tertiary obstetric units in Australia. POPULATION: Nulliparous women carrying an uncomplicated singleton term pregnancy. METHODS: Participants were assessed clinically and with 4D translabial ultrasound in the late third trimester, and again at 3-6 months postpartum. Women randomised to the intervention group were asked to use the Epi-No(®) device from 37 weeks of gestation until delivery. MAIN OUTCOME MEASURES: Levator ani, anal sphincter, and perineal trauma diagnosed clinically and/or with translabial ultrasound imaging. RESULTS: Of 660 women randomised, 504 (76.4%) returned for assessment at a mean of 5 months postpartum. There was no significant difference in the incidence of levator avulsion [12 versus 15%; relative risk (RR) 0.82, 95% confidence interval (95% CI) 0.51-1.32; absolute risk reduction (ARR) 0.03, 95% CI -0.04 to 0.09; P = 0.39], irreversible hiatal overdistension (13 versus 15%; RR 0.86, 95% CI 0.52-1.42; ARR 0.02, 95% CI -0.05 to 0.09; P = 0.51), clinical anal sphincter trauma (7 versus 6%; RR 1.12, 95% CI 0.49-2.60; ARR -0.01, 95% CI -0.05 to 0.06; P = 0.77), and perineal tears (51 versus 53%; RR 0.96, 95% CI 0.78-1.17; ARR 0.02, 95% CI -0.08 to 0.13; P = 0.65). A marginally higher rate of significant defects of the external anal sphincter on ultrasound was observed in the intervention group (21 versus 14%; RR 1.44, 95% CI 0.97-2.20; ARR -0.06, 95% CI -0.13 to 0.05; P = 0.07). CONCLUSION: Antenatal use of the Epi-No(®) device is unlikely to be clinically beneficial in the prevention of intrapartum levator ani damage, or anal sphincter and perineal trauma
dc.format.extent9
dc.identifier.citationKamisan Atan I, Shek KL, Langer S, Guzman Rojas R, Caudwell-Hall J, Daly JO, Dietz HP. Does the Epi-No(®) birth trainer prevent vaginal birth-related pelvic floor trauma? A multicentre prospective randomised controlled trial. BJOG. 2016 May;123(6):995-1003.
dc.identifier.urihttp://hdl.handle.net/11447/1231
dc.identifier.urihttp://dx.doi.org/10.1111/1471-0528.13924
dc.language.isoen_US
dc.publisherJohn Wiley & Sons
dc.subjectAnal sphincter tear
dc.subjectEpi-No®
dc.subjectlevator avulsion
dc.subjectpelvic floor trauma
dc.subjectperineal trauma
dc.titleDoes the Epi-No-(R) birth trainer prevent vaginal birth-related pelvic floor trauma? A multicentre prospective randomised controlled trial
dc.typeArtículo

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Does the Epi-No birth trainer prevent vaginal birth-related pelvic floor trauma A multicentre prospective randomised controlled trial.pdf
Size:
461.04 KB
Format:
Adobe Portable Document Format
Description:
Texto completo