Biomechanical and geometric characterization of peroneus longus allografts with respect to age
Date
2019
Type:
Article
item.page.extent
item.page.accessRights
item.contributor.advisor
ORCID:
Journal Title
Journal ISSN
Volume Title
Publisher
item.page.isbn
item.page.issn
item.page.issne
item.page.doiurl
item.page.other
item.page.references
Abstract
Background: Anterior cruciate ligament injuries are among the most common injuries in high impact sports, and reconstruction is the standard surgical procedure for these ruptures. Reconstructions are often performed using allografts rather than autografts on a case-by-case basis. Controversy exists as to whether or not age of donor tissue plays a factor in the mechanical properties of allografts.
Methods: 38 peroneus longus (PL) tendons were prepared using the two-strand graft technique and then subjected to a cyclic loading test regimen of 1000 cycles to determine material properties. Specimens were grouped based on age to ascertain whether donor age affects the material properties of PL tendons.
Findings: Secant modulus of the first cycle was determined to be 150.43 (SD 40.24) MPa. The average magnitude of the dynamic modulus was determined to be 82.81 (SD 24.65) MPa. Specimens were grouped into three distinct groups for analysis (x < 40 yo, 40 yo ≤ x < 60 yo, 60 yo < x).
Interpretation: The need for using intrinsic material properties is highlighted. There is no significant difference in any intrinsic material property with respect to age or the fatigue of the tendon as the cycle count increases. Conversely, the measured stiffness of a tendon decreased as function of age with a large effect size. Based on analysis of graft geometries, it was determined that PL tendons become significantly more slender with increased age which result in the observed decrease in stiffness.
Description
item.page.coverage.spatial
item.page.sponsorship
Citation
Wong AK, Calvo M R, Schaffler BC, Nixon RA, Carrero LC, Neufeld EV, Grande DA, Calvo R R. Biomechanical and geometric characterization of peroneus longus allografts with respect to age. Clin Biomech (Bristol, Avon). 2019 Jul;67:90-95. doi:10.1016/j.clinbiomech.2019.04.017
Keywords
ACL reconstruction, Biomechanics, Peroneus longus tendon