Inter-observer reliability of trained physiotherapists on the Functional Status Score for the Intensive Care Unit Chilean-Spanish version

dc.contributor.authorGonzález Seguel, Felipe
dc.contributor.authorCamus-Molina, Agustín
dc.contributor.authorCárcamo, Marcela
dc.contributor.authorHiser, Stephanie
dc.contributor.authorNeedham, Dale M.
dc.contributor.authorLeppe, Jaime
dc.date.accessioned2021-08-20T14:00:56Z
dc.date.available2021-08-20T14:00:56Z
dc.date.issued2020
dc.description.abstractPurpose: Evaluate inter-observer reliability of trained physiotherapists administering the Chilean-Spanish version of the Functional Status Score for the Intensive Care Unit (FSS-ICU).Methods: Six adult patients in a medical-surgical ICU were assessed and video-recorded by 1 of 2 expert physiotherapists. Twelve physiotherapists were then trained using recommended Spanish-language FSS-ICU materials. The 12 physiotherapists independently scored the FSS-ICU for the 6 video-recorded patients. Intraclass Correlation Coefficient (ICC) was used to evaluate the inter-observer reliability, and modified Bland-Altman plots evaluated agreement between the physiotherapists and experts.Results: This study was performed between May and August 2018. The FSS-ICU total score had a median score of 18 (range: 6 to 34) for the 6 patients. The ICC of the total score was 0.96 (95% CI, 0.92 to 1.00), and for each of the 5 individual FSS-ICU tasks, the ICC ranged between 0.87 and 0.92. The modified Bland-Altman plot revealed a mean difference of 0.6 (95% limits of agreement: -3.3 to 4.5).Conclusions: Twelve trained physiotherapists had excellent inter-observer reliability when administering the Chilean-Spanish FSS-ICU using videos of six critically ill patients, and had excellent agreement with an expert, revealing differences within the established minimal important difference. These findings provide new data supporting clinimetric properties of the Chilean-Spanish FSS-ICU.es
dc.format.extent8 p.es
dc.identifier.citationPhysiotherapy Theory and Practice. 2020 Apr 22;1-7es
dc.identifier.urihttps://doi.org/10.1080/09593985.2020.1753272es
dc.identifier.urihttp://hdl.handle.net/11447/4382
dc.language.isoenes
dc.subjectValidation studieses
dc.subjectMeasureses
dc.subjectMobility limitationes
dc.subjectPhysical functiones
dc.titleInter-observer reliability of trained physiotherapists on the Functional Status Score for the Intensive Care Unit Chilean-Spanish versiones
dc.typeArticlees

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Inter-observer reliability of trained physiotherapists on the Functional Status Score for the Intensive Care Unit Chilean-Spanish version - Felipe Andrés González Seguel.pdf
Size:
1.35 MB
Format:
Adobe Portable Document Format
Description:
Texto completo
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: