Accuracy of Power Mode TranscranialDoppler in the Diagnosis of Brain Death

dc.contributor.authorBrunser, Alejandro
dc.contributor.authorLavados, Pablo
dc.contributor.authorCárcamo, Daniel
dc.contributor.authorHoppe, Arnold
dc.contributor.authorOlavarría, Verónica
dc.contributor.authorLópez, Javiera
dc.contributor.authorMuñoz, Paula
dc.contributor.authorRivas, Rodrigo
dc.date.accessioned2021-11-23T22:48:56Z
dc.date.available2021-11-23T22:48:56Z
dc.date.issued2015
dc.description.abstractBackground:The diagnosis of brain death (BD) is complex. For this reason, we aimed toevaluate the accuracy of power mode transcranial Doppler (PMD-TCD) in diagnosing BD.Patients and methods:Patients admitted to an intensive care unit between December 2003and January 2012 were included in this study if they were in a structural coma, had nocraniectomy, and were evaluated blind by a neurologist using PMD-TCD. The diagnosis of BDwas based on an evaluation that took into consideration the absence of sedative drugs, amedian blood pressure>60 mmHg, a body temperature>35 C, and the absence of brainstemreflexes. A neurosonologist followed a protocol using PMD-TCD that considered the examina-tion as positive for brain circulatory arrest given the presence of reverberating, small systolicpeaks or the disappearance of a previous signal present in both middle cerebral arteries andintracranial vertebral arteries.Results:A total of 74 patients were evaluated. In 61 (82.4%) patients the interval betweenboth evaluations was less than 1 hour. The sensitivity and specificity for the diagnosis of BD with PMD-TCD were 100% and 98%, respectively. The positive and negative likelihood ratios forBD were 45 and 0, respectively.Conclusion:PMD-TCD is accurate for the diagnosis of BD.es
dc.identifier.citationAlejandro M. Brunser, Pablo M. Lavados, Daniel A. Cárcamo, Arnold Hoppe, Verónica V. Olavarría, Javiera López, Paula Muñoz, Rodrigo Rivas, Accuracy of Power Mode Transcranial Doppler in the Diagnosis of Brain Death, Journal of Medical Ultrasound, Volume 23, Issue 1, 2015, Pages 29-33,es
dc.identifier.urihttp://dx.doi.org/10.1016/j.jmu.2014.07.002es
dc.identifier.urihttp://hdl.handle.net/11447/5095
dc.language.isoen_USes
dc.subjectBrain deathes
dc.subjectDoppler ultrasoundes
dc.subjectPower mode transcranial Doppler ultrasoundes
dc.subjectUltrasound Doppler sonographyes
dc.subjectUltrasound diagnosises
dc.titleAccuracy of Power Mode TranscranialDoppler in the Diagnosis of Brain Deathes
dc.typeArticlees

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Accuracy of Power Mode Transcranial Doppler in the Diagnosis of Brain Death.pdf
Size:
701.5 KB
Format:
Adobe Portable Document Format
Description:
Texto completo
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: