Publication: Additive Value of EBUS-TBNA for Staging Non-Small Cell Lung Cancer in Patients Evaluated for Stereotactic Body Radiation Therapy
| dc.contributor.author | Boster, Joshua M. | |
| dc.contributor.author | Goertzen, S. Michael | |
| dc.contributor.author | Sainz, Paula V. | |
| dc.contributor.author | Rodríguez Vial, Macarena | |
| dc.contributor.author | Zaveri-Desai, Jhankruti K. | |
| dc.contributor.author | Luna, Luis D. | |
| dc.contributor.author | Grosu, Horiana B. | |
| dc.contributor.author | Waqar, Anum | |
| dc.contributor.author | Casal, Roberto F. | |
| dc.contributor.author | Jimenez, Carlos A. | |
| dc.contributor.author | Ost, David E. | |
| dc.contributor.author | Sabath, Bruce F. | |
| dc.contributor.author | Lin, Julie | |
| dc.contributor.author | Hernandez, Mike | |
| dc.contributor.author | Eapen, Georgie A. | |
| dc.date.accessioned | 2026-08-04T21:25:25Z | |
| dc.date.available | 2026-08-04T21:25:25Z | |
| dc.date.issued | 2025 | |
| dc.description.abstract | Background/Objectives: Patients with non-small cell lung cancer (NSCLC) being evaluated for stereotactic body radiation therapy (SBRT) are frequently staged non-invasively with positron emission tomography/computed tomography (PET/CT). Performing endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) in addition to PET/CT scanning may increase clinical certainty in lymph node staging, but the magnitude of added benefit of EBUS-TBNA over non-invasive staging methods is unclear. Methods: A single-center prospective cohort study involving patients with suspected or confirmed Stage I or IIa NSCLC referred for EBUS-TBNA prior to SBRT was performed. The primary outcome was concordance between PET/CT and EBUS-TBNA for nodal metastases. Secondary endpoints included sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of PET/CT, and clinical outcomes based on staging results. Results: Among 115 patients, the concordance between PET/CT and EBUS-TBNA was 84.3% (95% CI: 0.76 0.90). EBUS-TBNA led to a stage shift in 15.7% of cases: 4 of 98 PET/CT N0 patients (4.1%) had nodal metastases, while 14 of 17 PET/CT N1 patients (82.4%) were downstaged to N0. PET/CT sensitivity was 42.9% (95% CI: 0.09–0.81), specificity 87% (95% CI: 0.79–0.93), PPV 17.6% (95% CI: 0.04–0.43), and NPV 95.9% (95% CI: 0.90–0.99). PET/CT-positive, EBUS-TBNA-negative patients had worse survival (HR 4.25, 95% CI: 1.24–14.53, p = 0.021) compared with double-negative patients. Conclusions: EBUS-TBNA improves staging accuracy over PET/CT in early-stage NSCLC, impacting SBRT candidacy. However, PET/CT-positive, EBUS-TBNA-negative patients had worse outcomes in comparison to double-negative patients, suggesting a need for additional therapy or surveillance in that population. | |
| dc.description.version | Versión publicada | |
| dc.format.extent | 10 p. | |
| dc.identifier.citation | Boster, J. M., Goertzen, S. M., Sainz, P. V., Vial, M. R., Zaveri-Desai, J. K., Luna, L. D., Waqar, A., Grosu, H. B., Casal, R. F., Jimenez, C. A., Ost, D. E., Sabath, B. F., Lin, J., Hernandez, M., & Eapen, G. A. (2025). Additive Value of EBUS-TBNA for Staging Non-Small Cell Lung Cancer in Patients Evaluated for Stereotactic Body Radiation Therapy. Diagnostics, 15(17), 2136. https://doi.org/10.3390/diagnostics15172136 | |
| dc.identifier.doi | https://doi.org/10.3390/diagnostics15172136 | |
| dc.identifier.uri | https://hdl.handle.net/11447/10956 | |
| dc.language.iso | en | |
| dc.subject | Lung cancer | |
| dc.subject | Stereotactic body radiation therapy | |
| dc.subject | Bronchoscopic ultrasound | |
| dc.subject | Endobronchial ultrasound | |
| dc.subject | Staging | |
| dc.title | Additive Value of EBUS-TBNA for Staging Non-Small Cell Lung Cancer in Patients Evaluated for Stereotactic Body Radiation Therapy | |
| dc.type | Article | |
| dcterms.accessRights | Acceso abierto | |
| dcterms.source | Diagnostics | |
| dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- diagnostics-15-02136-v3.pdf
- Size:
- 2.52 MB
- Format:
- Adobe Portable Document Format