Publication:
Similar joint line convergence angle correction with mechanical and patient-specific alignment in robotic-assisted TKA

dc.contributor.authorFigueroa, David
dc.contributor.authorGonzalez, Waldo
dc.contributor.authorCalvo, Rafael
dc.contributor.authorIsla, Jorge
dc.contributor.authorFigueroa, Francisco
dc.date.accessioned2026-11-16T17:24:20Z
dc.date.available2026-11-16T17:24:20Z
dc.date.issued2025
dc.descriptionFree Full text
dc.description.abstractIntroduction: In total knee arthroplasty (TKA), positioning implants closer to the patient's constitutional alignment improves joint line obliquity (JLO), replicating normal biomechanics and gait patterns. As a result, the joint line convergence angle (JLCA) has gained recognition as a key parameter for assessing intra-articular deformity and lateral soft tissue laxity. This study aimed to evaluate JLCA changes following robotic-assisted TKA (RA-TKA) using two alignment strategies. We hypothesized that a patient-specific alignment (PSA) strategy would result in greater JLCA correction and improved outcomes. Methods: A retrospective review of 98 patients (100 knees) undergoing RA-TKA was performed. Group I (50 knees) underwent mechanical alignment (MA), while Group II (50 knees) underwent PSA. JLCA was measured preoperatively and postoperatively by two independent observers. Demographic and functional data, including KOOS JR scores were collected, and statistical analyses were performed using STATA v.18.5. Results: Both groups showed significant postoperative improvement in JLCA: from 2.34° to 0.35° in the MA group, and from 2.43° to 0.29° in the PSA group. However, the degree of JLCA correction did not differ significantly between groups (p = 0.285). KOOS JR scores improved similarly in both groups, with no significant differences at 1-year follow-up. Conclusions: Robotic-assisted TKA significantly improved JLCA regardless of alignment strategy. Patient-specific and mechanical alignment approaches yielded comparable radiographic and functional outcomes.
dc.description.versionVersión Aceptada
dc.identifier.citationFigueroa Poblete, D., Gonzalez Duque, W., Calvo Rodriguez, R., Isla Villanueva, J., & Figueroa Berrios, F. (2025). Similar joint line convergence angle correction with mechanical and patient-specific alignment in robotic-assisted TKA. Journal of orthopaedics, 69, 265–270. https://doi.org/10.1016/j.jor.2025.08.006
dc.identifier.doihttps://doi.org/10.1016/j.jor.2025.08.006
dc.identifier.urihttps://hdl.handle.net/11447/11374
dc.language.isoen
dc.subjectJoint line convergence angle
dc.subjectMechanical alignment
dc.subjectPatient-specific alignment
dc.subjectRobotic-assisted surgery
dc.subjectTotal knee arthroplasty
dc.titleSimilar joint line convergence angle correction with mechanical and patient-specific alignment in robotic-assisted TKA
dc.typeArticle
dcterms.sourceJournal of orthopaedics
dspace.entity.typePublication
relation.isAuthorOfPublication89dc716a-b080-4b0d-ab6d-36e3bd26c434
relation.isAuthorOfPublication.latestForDiscovery89dc716a-b080-4b0d-ab6d-36e3bd26c434

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Similar joint line convergence angle correction with mechanical and patient-specific alignment in robotic-assisted TKA.pdf
Size:
1.95 MB
Format:
Adobe Portable Document Format
Description:
Texto Completo
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
347 B
Format:
Item-specific license agreed upon to submission
Description: