Browsing by Author "Valencia, Oscar"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
Item Proximal and Distal Failure Site Analysis in Percutaneous Achilles Tendon Rupture Repair(Sage, 2019-12) Wagner, Pablo; Wagner, Emilio; López, Mario; Etchevers, Gastón; Valencia, Oscar; Guzmán, RodrigoBackground: Different techniques have been described for percutaneous Achilles tendon rupture repair, but no biomechanical evaluation has been performed separately for proximal and distal suturing techniques. The purpose of this study was to biomechanically analyze proximal versus distal percutaneous Achilles suture configurations during cyclic loading and load to failure. Methods: A simulated, midsubstance rupture was created 6 cm proximal to the calcaneal insertion in fresh-frozen cadaveric Achilles tendons. Fifteen proximal specimens were divided into 3 groups: (A1) triple locking technique, (A2) Bunnell-type technique, and (A3) double Bunnell-type technique. Twelve distal specimens were divided into 2 groups: (B1) triple nonlocking technique and (B2) oblique technique. Repairs were subjected to cyclic testing and load to failure. Load to failure, cause of failure, and tendon elongation were evaluated. Results: None of the proximal specimens and 7/12 of the distal ones failed in cyclic testing. The proximal fixation groups demonstrated significantly more strength than the distal groups (P = .001), achieving up to 710 N of failure load in Group A3. Groups B1and B2 failed on average at 380 N with no difference between them (P > .05). The majority of all repairs failed in the suture-tendon interface. Distal groups had more elongation during cyclic testing (13.7 mm) than proximal groups (9.4 mm) (P = .02). Conclusion: The distal fixation site in this Achilles tendon repair was significantly weaker than the proximal fixation site. A proximal modified suture configuration increased resistance to cyclic loading and load to failure significantly. Clinical relevance: A modification can be suggested to improve strength of the Achilles repair.Item Understanding the effect of window length and overlap for assessing sEMG in dynamic fatiguing contractions: A non-linear dimensionality reduction and clustering(2021) De la Fuente, Carlos; Martinez-Valdes, Eduardo; Priego-Quesada, Jose Ignacio; Weinstein, Alejandro; Valencia, Oscar; Kunzler, Marcos R.; Alvarez Ruf, Joel; Carpes, Felipe P.The Short-Time Fourier transform (STFT) is a helpful tool to identify muscle fatigue with clinical and sports applications. However, the choice of STFT parameters may affect the estimation of myoelectrical manifestations of fatigue. Here, we determine the effect of window length and overlap selections on the frequency slope and the coefficient of variation from EMG spectrum features in fatiguing contractions. We also determine whether STFT parameters affect the relationship between frequency slopes and task failure. Eighty-eight healthy adult men performed one-leg heel-rise until exhaustion. A factorial design with a window length of 50, 100, 250, 500, and 1000 ms with 0, 25, 50, 75, and 90% of overlap was used. The frequency slope was non-linearly fitted as a task failure function, followed by a dimensionality reduction and clustering analysis. The STFT parameters elicited five patterns. A small window length produced a higher slope frequency for the peak frequency (p < 0.001). The contrary was found for the mean and median frequency (p < 0.001). A larger window length elicited a higher slope frequency for the mean and peak frequencies. The largest frequency slope and dispersion was found for a window length of 50 ms without overlap using peak frequency. A combination of 250 ms with 50% of overlap reduced the dispersion both for peak, median, and mean frequency, but decreased the slope frequency. Therefore, the selection of STFT parameters during dynamic contractions should be accompanied by a mechanical measure of the task failure, and its parameters should be adjusted according to the experiment’s requirements.